Course Description
Introduces the new technician, and provides critical information for the experienced technician, on the theory and application of medium voltage cables. This includes a theoretical foundation on insulation science as it pertains to cable construction, termination and splicing of medium voltage cables including taping, heat shrink, cold shrink and elbows, and finally testing both with DC and VLF withstand and diagnostics.
This course is designed to provide the tools for an engineering technician or electrical worker to not simply learn one type of termination kit but to fully understand the technology of medium voltage cables, how to work with them, and how to evaluate their condition through testing. The course consists of five eight-hour days which include eight hours of insulation theory, twelve hours of cable termination training, eight hours of termination lab using both the 3M QTS and Elastimold separable connectors, and 12 hours of cable testing in the classroom and lab.
This course is anchored by an NCCER Level IV electrical module 26411, which is included for each trainee in the course. Upon successful completion, the trainee will be entered into the national registry and receive a certificate of completion for 35 contact hours equaling 3.5 CEU’s. This course requires 30 days advance planning due to the materials required.
Prerequisites: Proficiency in Basic and Advanced DC Theory and Basic AC Theory
Course Duration: 5 days at 8 hours per day – Monday through Friday
Course Objectives
- Describe the electrical and physical characteristics of medium voltage cables
- Select the proper materials and tools for medium-voltage terminations and splices
- Prepare medium voltage cable for terminations and splices
- Complete cable assemblies using terminations and splices
- Inspect and test medium-voltage terminations and splices
Performance Tasks
- Preparation and completion of a 3M QTS kit on 15kV shielded cable with a tape shield and an Elastimold separable connecter on 15kV concentric neutral cable
- Successfully complete a VLF Tangent Delta and Withstand test
Required Student Materials: NCCER 26411 Trainee Manual, 15kV cable and terminations (all provided as part of tuition)
Outcome Measurement: 15 Question Written Test / Practical
Grading Policy: Min. 70% to pass / PASS-FAIL
Location: Lewisville, TX
Pricing: Contact sales for pricing: [email protected] or [email protected]
This course can only be taught at the National Training Center. For more information contact us.